LEAK LOCATION, SEAL INSPECTION, FLUID ENGINEERING, DRY AIR PRESSURISATION EQUIPMENT
    
Worksite protection splice
dry air pressure systems

PRESSURISATION UNIT PARAMETER TRANSFER INTERFACE

Designed to enable the user to monitor the operating parameters of the air production sets, the IGP 94 parameter transfer interface for pressurisation sets is compatible with the majority of existing systems (ADECEF technology, CGEE, Soprano, Air Liquide, Gematel, Lancier, General Electric).

A kit which is specific to the set type enables all of the necessary electrical and pneumatic connections.

In its basic version, the IGP unit prepares and transfers all of the following parameters (in the same way as for a pressure sensor) in frequency form:

     » Buffer tank pressure (integrated sensor)
     » Outlet pressure (integrated sensor)
     » Emergency tank pressure (integrated sensor)
     » Dewpoint (if the existing sensor provides this information, otherwise properly operating NO or NF contact with configuration jumper accessible from outside the housing)
     » Global output (optional 0/5000 or 0/1000 L/H range sensor)
     » Compressor cycle time (buffer tank fill time)
     » Compressor operating time
     » 220V supply
     » 48V supply
 
The data coding format allows the forwarding of the parameters by means of REI or CMS software. Only CMS enables alarm thresholds to be set (minimum and maximum threshold alarms).
Querying can be performed using standard software but interpretation requires the use of nomograms. Only the TELG@T software enables the immediate display of the different data.
 
 

SPECIFICATIONS 
 

Dimensions  250 x 160 x 80 mm
Weight 1600 gr
Power supply 48VDC 0.2A
Pneumatic inputs 3 pressures - 0/2B 2x0/10B
Electrical inputs 4 TOR
3 x 0/5V analogue
Input fuse 0.315 amperes
Output:
Query line
Frequency encoded (900/1600)
Position from 1 to 10 set during manufacture
Conformant to EC and EN60950
 

Options

Flow metre IGP Débit (operating range to be specified by the user when the order is placed)
Hygrometer IGP Hygro

OUR CUSTOMERS

                                                                  PSA Peugeot Citroën Zehnder Baxi        
ADECEF Technology - 10 rue du Côteau - F-54180 HEILLECOURT France- Tel. : +33 3 83 52 75 62 - Fax : +33 3 83 52 72 05